REFUGE CHAMBER SEALING DOOR

于煤矿井下避难硐室过渡室与生存室之间

For the underground refuge room and living room between the transition chamber of coal mine

保护硐室内人员安全

一套两扇

Safety protection chamber A set of two fan

向外开启

起到能防水、防火、
防冲击波的作用

Open outwards, the waterproof, fire prevention,
the effect of shock wave.

锁闭机构采用双道紧密锁;门枢采用推力球轴承,方便开启。

避难硐密闭室门有门扇、门框为平钢板、筋板、型钢等组焊而成

在任何利益面前

安全总是被我们放在重要位置

当我们熟悉应急措施和注意事项

就可以把危险系数降到比较低

因产品生产批次、具体型号不同,图片仅供参考,详情可联系我们的销售人员进行具体核实

Because the production batches, the different models, the picture is for reference only
Please contact our sales staff for specific verification

注意事项/Matters needing attention

  • 进入避难硐室前,先通过防火密封门上的观察窗口查看过渡硐室内是否有人。如果有人正在洗气,等其结束洗气进入生存硐室并关闭生存硐室门后,硐室外的避险人员再打开过渡硐室门进入过渡硐室进行洗气。


    Into the refuge chamber before, first through the fire sealing observation window on the door to see whether the transition chamber someone. If someone is a gas washing, etc. the end gas washing into the living room and closed the door after the living chamber, chamber outdoor hedge personnel to open transition chamber door gas washing into the transition chamber.
  • 每次洗气人数不宜超过8人。


    Each gas washing number should not be more than 8 people.
  • 避难硐室正常运行状态下,应关闭CO2辅助硐室门。


    Refuge chamber under normal operation, should close the CO2 auxiliary chamber door.
  • 采用压风供氧硐室内共有4个压风供氧出口均需打开。


    The compressed air supply  chamber consists of 4 compressed air supply outlet shall be opened.
  • 采用O2供氧,当O2传感器显示O2浓度低于18.5%或高于23%时,可缓慢旋转O2流量计的旋钮来调节硐室内的O2浓度。


    The O2 oxygen sensor, O2 display when the O2 concentration is below 18.5% or above 23%, the concentration of O2 could knob slowly rotating O2 flow meter to adjust the chamber.
  • 当生存硐室内O2、CO和CO2的浓度达到人体呼吸要求O2浓度为18.5%, CO浓度小于24ppm,CO2浓度小于1%的安全浓度时方可取下配戴的自救器。


    When the concentration of O2, CO and living chamber CO2 to human respiratory O2 concentration 18.5%, CO concentration is less than 24ppm, the rescuer CO2 concentration less than safe concentration 1% square can wear.
  • 在压风被破坏的情况下,温度控制阀TCV-1、2 、3 、4中始终有至少一个处于开启状态。当生存硐室内的温度、湿度、CO浓度CO2浓度在安全范围内时可根据实际情况减少温度控制阀TCV-1、2 、3 、4开起的个数。


    The wind pressure is destroyed, the temperature control valve TCV-1, 2, 3, 4 has at least one in the fully open state. When living in indoor temperature, humidity, CO concentration of CO2 concentration in the safe range  can reduce the temperature control valve TCV-1, 2, 3, 4 opened the number according to the actual situation.
  • 当CO2压力小于600PSI、过滤除湿降温集成装臵无法正常运行时,打开紧急气体旁路系统控制阀延长装臵运行时间。


    When CO2 pressure is less than 600PSI, filter dehumidifying and cooling integrated. Unable to normal operation, open the extension installed. Run time valve control emergency gas bypass system.
  • 当生存硐室内CO2浓度无法降至1%以下、或吸附剂颜色变为浅紫色时更换CO2吸附剂。


    When living in indoor CO2 concentrations cannot be dropped to below 1%, or adsorbent color becomes shallow purple when replacing CO2 adsorbent.
  • 凹槽标识应和吸附剂标识CO一致,确保吸附剂放臵到正确的凹槽中。CO吸附剂一经充装放臵,请勿更换或移除。当生存硐室内CO浓度无法降至24ppm以下时更换CO吸附剂。


    Groove mark and logo CO adsorbent, adsorbent to ensure correct groove placed. The CO adsorbent was placed by filling, do not change or remove. When living in indoor CO concentrations cannot is reduced to less than 24ppm replace CO adsorbent.

安装施工/Installation and construction

  • 门的运输

    外门和内门运输到安装地点时采用3吨手拉葫芦,通过吊装从专用运输工具上卸下。运输中要防止破坏成品或碰撞伤人,到位卸下后,门下方应垫厚度不小于100mm的砧木,并放置平稳。门应处于关闭锁紧状态。

  • 门的固定

    安装时首应先确定两道门的安装位置;在安装位置的顶部施工两根锚杆并临时固定好葫芦,用葫芦通过吊装孔将内门框(与门扇一起)提起到安装位置,检测其门框的水平和垂直,位置调整准确后,用木方或砖块将门垫稳卡牢,进行临时固定。安装时先进行内门的安装施工,内门框墙体施工建设完成,检查内门开启无误后,再进行外门的安装施工。

    门框墙施工

    内外门框墙厚度要求都为700mm,墙体整体浇筑。采用砖胎膜,厚度为120mm,中间夹层用钢筋混凝土浇筑。

维护保养/Maintenance

凡有防锈料脱落或碰掉处均应随时补涂。

密封橡胶条如有损伤或脱胶应及时更换或粘接,密封条更换期为2年左右。

门枢转动部分如有锈蚀应擦洗干净并应重新涂油。

安装使用后,至少半年保养检修一次。

密封胶条应经常涂滑石粉,防止老化。